Commodity |
Nasogastric tubes |
|||
Type |
PVC |
PUR Gravity |
PUR with Weighted tip |
|
Code |
BECX1 |
BECX2 |
BECG2 |
|
Length |
120cm |
110cm/130cm |
110cm/130cm/150cm |
|
Tube size |
CH12/14/16 |
CH8/10/12/14/16 |
||
Material |
PVC |
PUR (Good biocompatibility ) |
||
Application |
For gastrointestinal decompression |
For tube feeding |
||
Package |
Sterile single pack |
|||
Weighted tip |
- |
- |
Ball/Column |
|
Radiopaque line |
Radiopaque line throughout the length |
|||
Depth marked |
Depth marked on the tube |
|||
Note |
Different configuration for choice |
PVC is suitable for gastrointestinal decompression and short-term tube feeding;
PUR high-end material, good biocompatibility, little irritation to the patient’s nasopharyngeal and
digestive tract mucosa, suitable for long-term tube feeding;
Multiple specifications and configurations to meet different clinical needs:
Provide CH8 to CH16 various tube diameters and length;
Tube placement is easy and smooth:
The tube is equipped with a guidewire, which can also be placed in patients with coma and swallowing dysfunction; the tube wall is coated with a hydrophilic layer to facilitate the extraction of the guidewire;
Accurate positioning after tube placement:
The tube body is marked with a scale, and the X-ray radiopaque line is convenient for positioning
after the tube is placed;
Two patented designs of weighted tip:
The 2 weighted tip structure prevents gastric reflux from accidentally escaping the tube; the standard weighted tip structure can assist the tube to enter the small intestine for feeding with the gastric dynamics;
Can be used directly in the operating room:
With disinfect paraffin oil bag, it is convenient for clinical operation
· The guidewire is far away from the opening of the tube, will not be accidentally exposed, and the guidewire can be inserted and removed repeatedly
· The end hole at the end of the tube can be passed through the interventional guidewire, which is convenient for tube placement under X-ray
· There are two lateral holes, and the distance between the lateral holes is short.
· After the tip of the tube passes through the pylorus, it is not easy for the lateral hole to stay in the stomach. The outflow of nutrient solution can cause stomach irritation and is more suitable for small intestine feeding.
Lateral hole:
· Decompression and suction of large lateral holes are smooth, and self-made liquid feeding can be carried out
· Direct heat sealing technology is used on the top, the surface is rounded, which reduces the stimulation of the digestive tract mucosa when the tube is placed